Click on the application to view only its related inserts.
(If no application has been selected
all
related inserts will be displayed)
www.iscar.com
Reset
Tooling Systems
Main Application
Profiling
Sub Application
New Search
More Info
Related Tool
Related Holder
Machine Power
Search Path
HSK E-ER :
DIN6499 ER collet chucks with HSK DIN69893 form E tapered shanks.
Designation
SS
CSI
d
min
d
max
D3
D2
L
L1
L3
J
Kg
HSK E 32 ER16X 60
32
ER16
0.5
10.0
28.00
22.40
60.00
40.0
21.50
-
0.22
HSK E 32 ER20X 60
32
ER20
1.0
13.0
34.00
25.40
60.00
40.0
26.00
-
0.18
HSK E 32 ER25X 65
32
ER25
1.0
16.0
42.00
25.80
65.00
45.0
30.00
-
0.20
HSK E 40 ER16X 60
40
ER16
0.5
10.0
28.00
-
60.00
40.0
-
-
0.28
HSK E 40 ER16X 80
40
ER16
0.5
10.0
28.00
-
80.00
60.0
-
M10
0.36
HSK E 40 ER20X 80
40
ER20
1.0
13.0
34.00
-
80.00
60.0
-
M12
0.44
HSK E 40 ER25X 80
40
ER25
1.0
16.0
42.00
34.00
80.00
60.0
28.00
M18X1.5
0.42
HSK E 40 ER32X 80
40
ER32
2.0
20.0
50.00
40.10
80.00
60.0
31.00
M22X1.5
0.41
HSK E 50 ER16X 80
50
ER16
0.5
10.0
28.00
-
80.00
54.0
-
M10
0.55
HSK E 50 ER16X100
50
ER16
0.5
10.0
28.00
-
100.00
74.0
-
M10
0.64
HSK E 50 ER16X100 M
50
ER16
0.5
10.0
22.00
-
100.00
74.0
-
M10
0.55
HSK E 50 ER20X 80
50
ER20
1.0
13.0
34.00
-
80.00
54.0
-
M12
0.60
HSK E 50 ER25X 80
50
ER25
1.0
16.0
42.00
32.40
80.00
54.0
28.00
M16
0.56
HSK E 50 ER32X 80
50
ER32
2.0
20.0
50.00
40.40
80.00
54.0
31.00
-
0.63
HSK E 50 ER32X100
50
ER32
2.0
20.0
50.00
40.40
100.00
74.0
31.00
M22X1.5
0.78
HSK E 63 ER16X 80
63
ER16
0.5
10.0
28.00
-
80.00
54.0
-
M10
0.92
HSK E 63 ER16X100
63
ER16
0.5
10.0
28.00
-
100.00
74.0
-
M10
1.01
HSK E 63 ER20X 75
63
ER20
1.0
13.0
34.00
-
75.00
49.0
-
-
0.90
HSK E 63 ER32X 80
63
ER32
2.0
20.0
50.00
40.40
80.00
54.0
31.00
-
0.91
HSK E 63 ER32X100
63
ER32
2.0
20.0
50.00
-
100.00
75.0
-
M22X1.5
1.28
HSK E 63 ER40X 80
63
ER40
3.0
26.0
63.00
-
80.00
54.0
34.00
-
0.99
A cooling tube must be used with all coolant through HSK spindles (should be ordered separately).
For shank dimensions, Click on "More Info".
Balanced to G2.5/25,000 RPM.
ISCAR can not guarantee an unbalance value less than 1 gr x mm.
Terms of Use and Legal Disclaimer